I have been meaning to build a ventilation fan for some time now, and all the recent ones posted spurred me to actually do it. Because of space restrictions, and what I had available to me, I went with tube fans rather than a squirrel cage fan. They are each rated at 1590 CFM, but that is reduced by the filters, so I am not sure what I am actually getting. However, as seen in the last picture it does work as evidenced by the dust on the filter (I used my air compressor to "kick up some dust" to test it).

I decided to insulate between the fans primarily in an effort to make sure air was only moving back to front. I do not think this would be as much of an issue in tube fans as it would in squirrel cage fans, but I figured "why not?". This also helped cut the noise down a bit, which I did not expect since the motors are inline with the airflow.

I originally designed it for either two 1" filters, or one 1" filter and a layer of the same filter material you might find on the back of a humidifier. However, that really seemed to cut down on airflow. Once it was hung I changed the plan a bit and added angle iron to make a bracket for the filter. With one filter there is much better flow, and it is easier to change as I do not have to cut the filter to fit the box. Rather than building the box to fit the filter I had to make the box fit my space and the filter fit it. What cannot be seen in the pictures is that the extra 2" of the filter at the top are between rafters, while the box itself is attached to the bottom of them.

I took an idea from another fan post here on LJs and used a Christmas light timer. That way I not only have the remote, but can set it for two hour increments up to 12 hours, or just have it on all the time. So far it seems to be working well, but I am going to play with different filter combinations. I am thinking of adding one to the front to catch anything that makes it through the rear, but CFM reduction will have to be taken into consideration.

Specs:

1/2" ply
24" wide
10" high
Glued and stapled except for the bottom and front which were screwed to allow access
Fans: (74.99 plus a 20% coupon off the entire order) http://www.harborfreight.com/8-inch-portable-ventilator-97762.html

As always thoughts and ideas are appreciated. I would love to make it even more efficient if anyone has ideas for that.

Gallery

Comments

·
Registered
Joined
·
19,961 Posts
Looks like it will work well, with the right filter. What MERV rating is your filter?

In order to remove the harmful fines, one needs around a 10 -15 MERV rating.

You should be able to enjoy a cleaner shop and healthier lungs. Good job!
 

·
Registered
Joined
·
169 Posts
Where would one find the ratings? I looked and looked (mostly for how many microns it would filter) and all I could find was each manufacturer's model numbers (600, 1500, ultra-allergen, etc.) and a pictorial representation of what it was supposed to filter out. I will go back and see if there is anything about MERV on the packaging. (What does MERV mean or equate to?)
 

·
Registered
Joined
·
19,961 Posts
Here is a WIKI on MERV ratings.
 

·
Registered
Joined
·
169 Posts
Thanks!
 

·
Registered
Joined
·
19,961 Posts
Opps,
It had info when I posted it?!? Weird!!!
Too late for me to edit it!

Thanks, essexry!!!
 

·
Registered
Joined
·
234 Posts
Now that is what I needed to see! Thanks for posting!!
 

·
Registered
Joined
·
10,969 Posts
I like the timer idea, for my shop vacuum I installed a small light fixture with a red bulb. If I forget to turn off the shop vac the red light reminds me it is on when I cut the shop lights. Since my hearing is poor, and the shop vac is enclosed in an outside building I could leave it on all day and night. (laughing)
 

·
Registered
Joined
·
169 Posts
Great idea with the light. Asm, no problem, glad it helped.
 