Can a table saw breaker go bad?

by NTXSteve
posted 11-21-2018 07:09 PM


10 replies so far

View RobHannon's profile

RobHannon

266 posts in 926 days


#1 posted 11-21-2018 08:07 PM

Certainly can go bad. You should be able to visual check the brushes, but I think those are unlikely. If it is not internal to the motor, the part is probably pretty easy to replace. See if it shows up on a parts diagram somewhere.

View MrUnix's profile

MrUnix

7388 posts in 2595 days


#2 posted 11-21-2018 08:18 PM

Yes, they can go bad over time.. and they can get worse the more trips they suffer (particularly the bi-metalic thermal types). However, it could also be something else, such as a loose connection, bad run capacitor on an induction motor, worn brushes on a universal motor, improper wiring (ie: long extension cords, or wired for 240v and running on 120v). What model saw are we talking about and how long has this been happening?

Cheers,
Brad

-- Brad in FL - In Dog I trust... everything else is questionable

View fuigb's profile

fuigb

559 posts in 3353 days


#3 posted 11-21-2018 08:30 PM

The problem occurs when you run the saw on a different circuit? Panel breakers can fail too, which is why you should isolate the problem to the saw by eliminating other possibilities.

-- - Crud. Go tell your mother that I need a Band-aid.

View NTXSteve's profile

NTXSteve

6 posts in 1271 days


#4 posted 11-21-2018 08:57 PM

Thanks for the responses. It’s a Jet JWSS-10C and has served me well for nearly 15 years. I’ve isolated it to the saw by testing on multiple circuits, all dedicated, with the same results. It’s plugged in properly and I’ve checked all the wiring that I can find and see no loose connections. Just ran to Grainger and got a new breaker for it. I’m going to install it and see if that helps – I’ll report back with what I find.

Any other “common” things I can check/replace? I definitely don’t want it to turn into a more expensive proposition…

View GR8HUNTER's profile

GR8HUNTER

6110 posts in 1108 days


#5 posted 11-21-2018 11:39 PM

very possible that breaker itself failed or switch :<((

-- Tony---- Reinholds,Pa.------ REMEMBER TO ALWAYS HAVE FUN

View NTXSteve's profile

NTXSteve

6 posts in 1271 days


#6 posted 11-22-2018 12:12 AM

Well, after replacing the 15A thermal breaker, it looks like that may have been the culprit. With the new breaker I was able to rip several dozen 2×4’s and only tripped it once – mostly my doing as I was trying t see how hard I could push it before it tripped.

My only concern is that I was still able to trip it while ripping pine – I’m wondering how much of a load it should be able to handle before the breaker trips?

View GrantA's profile

GrantA

1512 posts in 1803 days


#7 posted 11-22-2018 12:29 AM

How’s the blade? A dull blade could bog down even with easily cut materials. Also you say “pine” but are we talking dense resinous pine or box store new growth white/yellow pine? The two will behave much differently. Blade could just need cleaned too, if you’ve been cutting pine it’s probably caked with buildup. In that case you should be getting burn marks on the wood too

View splintergroup's profile

splintergroup

2697 posts in 1618 days


#8 posted 11-22-2018 03:28 PM

Those import-lowest-cost pushbutton breakers fail all the time (I’ve had several go). Brad is correct in that they get weaker every time they pop.
Replace them with a quality unit, not the lowest price unit. I’ve had good luck with stuff from mcm electronics.

View NTXSteve's profile

NTXSteve

6 posts in 1271 days


#9 posted 11-27-2018 03:37 AM

GrantA, all very good points, but it’s a brand new blade cutting wonderfully. And some of the pine is a bit more dense, but overall mostly easy-cutting. I had just started the project so no real buildup of any kind.

Splinter, you’ve hit on something there. The one I replaced it with, although working now, was probably not the highest quality – just what I found at the closest place. So it looks like some time spent on the mcm electronics site is in my future :)

Thanks everyone for the thoughts! I love to learn and this board with all your experiences is quite good at that!

View WoodenDreams's profile

WoodenDreams

610 posts in 307 days


#10 posted 11-27-2018 09:34 AM

most likely a breaker, but I’d also look at the bushings, since you said it’s 15 years old.

Have your say...