LumberJocks

Reply by Manitario

  • Advertise with us

Posted on Clear Vue EF5 dust collector input

View Manitario's profile

Manitario

2816 posts in 3737 days


#1 posted 12-08-2018 04:18 AM



There s something else going on if you can only pull 95 CFM through a single 4” duct with a CV 1800. that doesn t make sense.

- Fred Hargis

Sorry, should have been 195 CFM. Still pretty poor. Measured with a Dwyer digital manometer and pitot tube and the exact same procedure as the other CFM measurements I posted.

-- Sometimes the creative process requires foul language. -- Charles Neil


DISCLAIMER: Any posts on LJ are posted by individuals acting in their own right and do not necessarily reflect the views of LJ. LJ will not be held liable for the actions of any user.